BH Curve and Coercivity Measurement: Methods, Equipment and Selection
2026-11-26 · FAQ
Short answer: surface field inspection cannot replace coercivity measurement
Surface field inspection measures the field at a point on a magnet’s surface — it reflects the result after magnetizing. BH curve measurement characterizes the material’s demagnetization behaviour and returns remanence Br, induction coercivity Hcb, intrinsic coercivity Hcj and maximum energy product BHmax. The first suits 100% inline screening; the second suits incoming inspection, grade confirmation and demagnetization-resistance analysis. One cannot be converted into the other.
A common mistake is to conclude that coercivity is low because surface field is low. Surface field depends strongly on geometry, size, probe distance and magnetizing fixtures; for the same grade, geometry alone can cause a wider spread than the batch-to-batch spread. When demagnetization resistance is the question, measure the BH curve.
Three methods and when to use them
| Method | Parameters | Sample | Notes |
|---|---|---|---|
| DC closed-loop permeameter | Br, Hcb, Hcj, BHmax, full demagnetization curve | A/B standard samples, small magnets, motor magnet slices | Closed magnetic circuit, efficient field use, repeatable; incoming inspection and laboratory work |
| Pulsed-field BH measurement | Demagnetization curve and main magnetic parameters | High-coercivity NdFeB, full magnets | Very high peak field and short cycle; temperature and system errors need control |
| Helmholtz coil / fluxmeter | Total flux and magnetic moment — not Hcj directly | Full magnets and assemblies | Fast sorting, not a substitute for coercivity values |
The DKP series DC permeameter belongs to the first group (material-level BH and coercivity work). For pole distribution and consistency on the line, use a surface field inspection system; for complete motor stations, see motor test systems.
Reading the four key parameters
- Br (remanence): flux density remaining after the external field is removed — how much flux the magnet can supply.
- Hcb (induction coercivity): reverse field required to reduce B to zero.
- Hcj (intrinsic coercivity): reverse field required to reduce M to zero. This — not surface field — indicates resistance to demagnetization in motor magnets.
- BHmax (maximum energy product): maximum B×H on the demagnetization curve, a measure of stored magnetic energy.
EV traction magnets are usually evaluated by how much Hcj drops at elevated temperature. For high-temperature coercivity testing, heat the sample and fixture together to the target temperature, allow it to stabilize, then run a full demagnetization–remagnetization cycle. Room-temperature data alone cannot assess hot demagnetization risk.
Where measurement error comes from
- Incomplete saturation: if the magnetizing field is too low, the curve does not represent the material and Hcj is underestimated.
- Air gap and clamping: gaps between sample and pole faces introduce demagnetizing fields; non-parallel end faces hurt repeatability.
- Temperature drift: NdFeB coercivity has a significant temperature coefficient; test conditions must match the application.
- Sample geometry: non-standard samples need demagnetizing-factor correction — standard-sample values cannot be reused directly.
Three inputs are enough to select a system: sample size and shape, the parameters required (Br/Hcj only or a full curve), and whether high-temperature testing is needed. Once these are fixed, the permeameter model and fixture design follow.
On the line: 100% surface field screening plus BH sampling
Inline inspection favours cycle time, so it measures peak surface field, pole count, polarity and angle. BH curve measurement takes longer and is normally used for incoming sampling, first-article checks and failure analysis. Linking the two data sets lets surface field act as a fast screen while BH data periodically validates the screening criteria.
To configure a system for your part size, range and cycle time, see our equipment range or contact an engineer for a selection proposal and report template.
Find equipment by measurement task
Each measurement task has one dedicated landing page — from surface field inspection and deviation angles to BH curves, coercivity and motor testing.
Surface Field Inspection
Surface field mapping for magnets, rings and motor rotors, with automatic pole, polarity and peak-angle analysis.
View equipment →02Magnetic Field Measurement
From handheld gaussmeters to multichannel systems and field cameras — single point, spatial mapping and weak-field work.
View equipment →03Magnetic Deviation Measurement
Measure the angle between a permanent magnet’s magnetic moment and its geometric axis after magnetizing.
View equipment →04BH Curve Measurement
DC permeameter measurements of the demagnetization curve: Br, Hcb, Hcj and maximum energy product.
View equipment →05Coercivity Measurement
Intrinsic and induction coercivity testing to assess resistance to demagnetization and high-temperature margin.
View equipment →06Motor Testing
Integrated motor test systems and rotor surface field inspection, configured by model, cycle time and station.
View equipment →07Field Mapping
One- to three-dimensional field scanning for large magnetic assemblies and complete equipment.
View equipment →08Magnetic Shielding
Low-remanence shielding barrels and ultra-low-noise platforms for weak-field test environments.
View equipment →Further reading: BH Curve and Coercivity Measurement: Methods, Equipment and Selection